专业提供英国阻燃测试、法国阻燃测试、德国阻燃测试、欧盟阻燃测试、美国阻燃测试、意大利阻燃测试、船舶阻燃测试、国标阻燃测试、飞机阻燃测试

联系我们

电话:400-603-6575
          025-86583475
邮箱:info@fire-test.com

地址:江苏省南京市建邺区江东中路              118号德盈大厦16F

相关测试

测试标准

首页    材料测试    AS/NZS 4859.1玻璃棉岩棉等保料澳标认证

AS/NZS 4859.1玻璃棉岩棉等保料澳标认证

玻璃棉岩棉等保温材料出口澳大利亚需满足AS/NZS 4859.1的标准要求,产品经过测试合格并经过严格的工厂评估后,即可颁发StandardMark认证证书。AS/NZS 4859.1:2018新标准有哪些变化?更新了导热值(R值)的计算和声明方式。更多关于澳标AS4589.1认证,请咨询南京睿督公司,咨询电话:025-86583475。

◆ 澳标AS/NZS 4859.1:2018

AS/NZS 4859.1:2018 Materials for the thermal insulation of buildings - General criteria and technical provisions
AS/NZS 4859.1:2018 标准概述了建筑物隔热材料的一般标准和技术规定。

单个材料或绝缘类型的具体要求:
(1) 硬质泡沫聚氨酯(RC/PUR)-AS 1366.1;
(2) 硬质多孔聚异氰尿酸盐(RC/PIR)-AS 1366.2;
(3) 硬质泡沫聚苯乙烯模塑(RC/PS-M)-AS 1366.3;
(4) 硬质多孔挤塑聚苯乙烯(RC/PS-E)-AS 1366.4;
(5) 脲醛泡沫保温原位凝固泡沫-AS 4073。

(a) Rigid cellular polyurethane (RC/PUR) - AS 1366.1;
(b) Rigid cellular polyisocyanurate (RC/PIR) - AS 1366.2;
(c) Rigid cellular polystyrene Moulded (RC/PS-M) - AS 1366.3;
(d) Rigid cellular polystyrene Extruded (RC/PS-E) - AS 1366.4; and
(e) Urea-formaldehyde foam thermal insulationIn situ set foam - AS 4073.
The scope of this Standard does not cover requirements for fire performance


 

◆ AS/NZS 4859.1:2018新标准有哪些变化?

更新了导热值(R值)的计算和声明方式。修订后的标准AS/NZS 4859.1:2018的大变化与热试验和性能标签的正式声明有关:热测试:对于根据本标准评估的每种材料,需要对至少10个测试结果进行统计评估。该统计评估应根据统计调整的平均值确定测试产品的R值和导热系数,该平均值代表50%的分位数,单侧公差区间的置信度为90%。表示为R50/90或λ50/90。相同的统计评估适用于所有绝缘材料,真空绝缘板除外。

◆ How is it Changing AS/NZS 4859.1:2018?

√ A statistical assessment of at least 10 test results is required for each material assessed under the standard.

√ This statistical assessment shall determine the R-value and thermal conductivity for the products tested from the statistically adjusted mean values representing a 50% fractile with 90% confidence for a one-sided tolerance interval. To be expressed as R50/90 or λ50/90.

√ The same statistical assessment is applicable for all insulation materials, except for vacuum insulation panels.


 

◆ 南京睿督| 防火阻燃检测 | 构件耐火性能检测

 

https://www.fire-test.com/newsinfo/4260230.html 


建筑材料:GB 8624, EN 13501-1, BS 476-4, BS 476-6, BS 476-7, DIN 4102-1, NF P92-501, NF P92-503,NF P92-507,ASTM E162, ASTM E84,ASTM E648,EN ISO 5660-1,ISO 5658-2,ISO 1716,EN 4589, AS 1530.1, AS 1530.3,ASTM E662, ISO 5659-2
参考链接:https://www.fire-test.com/newsinfo/4260230.html 