测试标准

首页    其他测试及认证    南京睿督提供DAkkS资质门窗荷载阻力/耐久性标准检测

南京睿督提供DAkkS资质门窗荷载阻力/耐久性标准检测

南京睿督公司为Notified Body欧盟公告号实验室授权合作机构,专业提供门窗CE认证及相关性能检测。同时提供德国DAkkS资质门窗荷载承重等标准检测,具体内容请咨询南京睿督公司,咨询电话:025-86583475。

Testing concerning operability, continuous performance,resistance against ageing behaviour under mechanical and environmental influences
关于机械和环境影响下的可操作性、连续性能、抗老化性能的测试

DIN EN 947 1999-05 Hinged or pivoted doors - Determination of the resistance to vertical load 
DIN EN 948 1999-11 Hinged or pivoted doors - Determination of the resistance to static torsion 
DIN EN 949 1999-05 Windows and curtain walling, doors, blinds and shutters - Determination of the resistance to soft and heavy body impact for doors 
DIN EN 950 1999-11 Door leaves - Determination of the resistance to hard body impact 
DIN EN 951 1999-05 Door leaves - Method for measurement of height, width, thickness and squareness 

DIN EN 952 1999-11 Door leaves - General and local flatness - Measurement method 
DIN EN 1191 2013-04 Windows and doors - Resistance to repeated opening and closing - Test method 
DIN EN 12046-1 2004-04 Operating forces - Test method - Part 1: Windows 
DIN EN 12046-2 2000-12 Operating forces - Test method - Part 2: Doors
DIN EN 13126-1 2012-02 Building hardware - Hardware for windows and door height windows - Requirements and test methods - Part 1: Requirements common to all types of hardware 

DIN EN 13126-2 2011-12 Building hardware - Requirements and test methods for windows and door height windows - Part 2: Window fastener handles
DIN EN 13126-3 2012-02 Building hardware - Hardware for windows and door height windows - Requirements and test methods - Part 3: Handles, primarily for Tilt and Turn, Tilt-First and Turn-Only hardware
DIN EN 13126-4 2009-01 Building hardware - Requirements and test methods for windows and doors height windows - Part 4: Espagnolettes
DIN EN 13126-5 2012-02 Building hardware - Hardware for windows and balcony doors - Requirements and test methods - Part 5: Devices that restrict the opening of windows and door height windows
DIN EN 13126-6 2009-02 Building hardware - Requirements and test methods for windows and doors height windows - Part 6: Variable geometry stay hinges (with or without a friction stay) 

DIN EN 13126-7 2007-12 Building hardware - Requirements and test methods for windows and door height windows - Part 7: Finger catches 
DIN EN 13126-8 2006-05 Building hardware - Requirements and test methods for windows and doors height windows - Part 8: Tilt & Turn, Tilt-First and Turn-Only hardware 
DIN EN 13126-9 2013-04 Building hardware - Hardware for windows and door height windows - Requirements and test methods - Part 9: Hardware for horizontal and vertical pivot windows
DIN EN 13126-10 2009-02 Building hardware - Requirements and test methods for windows and doors height windows - Part 10: Arm-balancing systems 
DIN EN 13126-11 2009-02 Building hardware - Requirements and test methods for windows and doors height windows - Part 11: Top hung projecting reversible hardware

DIN EN 13126-12 2009-03 Building hardware - Requirements and test methods for windows and doors height windows - Part 12: Side hung projecting reversible hardware 
DIN EN 13126-13 2012-08 Building hardware - Hardware for windows and balcony doors - Requirements and test methods - Part 13: Sash balances 
DIN EN 13126-14 2012-08 Building hardware - Hardware for windows and balcony doors - Requirements and test methods - Part 14: Sash fasteners 
DIN EN 13126-15 2008-04 Building hardware - Requirements and test methods for windows and doors height windows - Part 15: Rollers for horizontal sliding and sliding folding windows and doors 
DIN EN 13126-16 2008-04 Building hardware - Requirements and test methods for windows and doors height windows - Part 16: Hardware for Lift&Slide windows and doors 

DIN EN 13126-17 2008-04 Building hardware - Requirements and test methods for windows and doors height windows - Part 17: Hardware for Tilt&Slide windows and doors 
DIN EN 13527 2001-01 Shutters and blinds - Measurement of operating force - Test methods 
DIN EN 14608 2004-09 Windows - Determination of the resistance to racking (Racking) (partial replacement for DIN EN 107)
DIN EN 14609 2004-09 Windows - Determination of the resistance to static torsion (partial replacement for DIN EN 107)
DIN 4102-18 1991-03 Fire behaviour of building materials and components - Part 18: fire barriers, verification of automatic closure (continuous performance test) 

AAMA 501-4 2000 Revision 2009 Recommended Static Test Method for Evaluating Curtain Wall and Store-front Systems Subjected to Seismic and Wind Induced Interstory Drifts
AAMA 501-6 Revision 2009 Recommended Dynamic Test Method for Determining the Seismic Drift Causing Glass Fallout from a Wall System R
RAL-RG 607-3 1995-03 Turn and tilt and turn hardware -Quality control

门窗CE认证相关阅读
CPR法规 http://www.hksmartps.com/ce/cpr/
建材CE认证 http://www.hksmartps.com/ce
门窗CE认证 http://www.hksmartps.com/ce/windowanddoor
门窗CE认证协调标准汇总 http://www.hksmartps.com/ce/windowanddoor/4350.html
EN 14351-1:2006+A2:2016门窗CE认证最新协调标准/入户门CE认证/窗CE认证http://www.hksmartps.com/cekonwledge/4530.html

南京睿督公司为欧盟公告号实验室授权合作实验室,专业提供门窗CE认证。
南京睿督全国免费咨询电话:400-603-6575 025-8658 3475
网址:www.hksmartps.com    www.cprce.com 