DIN54837/DIN5510-2 S2、S3、S4、S5 testing
DIN54837:2007 the test method is used to DIN 5510-2 in the S2-S5 burning level test. DIN 54837 the test can also smoke development (does not meet the SR1, SR1-SR2) and droplet test (ST1-ST2)
DIN 54837:2007 Testing of materials, small components and component sections for rail vehicles-Determination of burning behaviour using a gas burner.
DIN54837 the test method is used to DIN 5510-2 in the S2-S5 burning level test
S2 Classification for DIN5510-2: damage range ≤ 30cm
S3 Classification for DIN5510-2: damage range ≤ 25cm, after the burning time ≤ 100S
S4 Classification for DIN5510-2: damage range ≤ 20cm, after the burning time ≤ 10S
S5 Classification for DIN5510-2: damage range = 0cm, after the burning time = 0S
DIN 54837 the test can also smoke development (does not meet the SR1, SR1-SR2) and droplet test (ST1-ST2)
S2- S5 Classification flammability testing
classification |
S2 |
S3 |
S4 |
S5 |
damage range |
≤ |
≤ |
≤ |
|
after the burning time |
No requirement |
≤100s |
≤10s |
0s |
Smoke development classification
classification |
requirement |
Not meet the SR1 |
>100(%*min) |
SR1 |
≤100(%*min) |
SR2 |
≤50(%*min) |
Droplet testing
classification |
requirement |
ST1 |
Droplet |
ST2 |
No Droplet |
DIN5510-2:2009-05 the latest test version of EN ISO 5659-2 increased the toxicity test.