²âÊÔ±ê×¼
 
Ïà¹Ø²âÊÔ
 
ÁªÏµÎÒÃÇ
µØÖ·£ºÖйú½­ËÕÊ¡ÄϾ©Êн­¶«Öз118ºÅµÂÓ¯´óÏÃ16F
µç»°£º(+86) 025-8658 3475
´«Õ棺(+86) 025-8658 3457
ÓÊÏ[email protected]
 

ÃÀ¹úElementʵÑéÊÒASTM E595 outgassing³ýÆø²âÊÔ


ÄϾ©î£¶½¹«Ë¾ÎªÃÀ¹úELEMENTʵÑéÊÒºÏ×÷£¬Îªº½Ìì²ÄÁÏÑо¿²âÊÔÌṩ¸ßÆ·ÖʵĵØÃæÄ£Äâ¿Õ¼ä»·¾³²âÊÔ¼°½â¾ö·½°¸¡£º½¿Õº½Ìì²ÄÁϼ°5G¸ß¿Æ¼¼ÁìÓò¶ÔÓÚ²ÄÁϵÄÐÔÄÜÒªÇó·Ç³£¸ß£¬ÄϾ©î£¶½¹«Ë¾ÓëÃÀ¹úȨÍþʵÑéÊÒºÏ×÷ÌṩASTM E595£¬ASTM E1559µÈ±ê×¼µÄÍÑÆø²âÊÔoutgassing test£¬×Éѯµç»°£º025-8658 3475¡£


ASTM E595
Ϊº½¿Õº½ÌìºÍ5GµÈÌØÊⳡËùÓ¦ÓòÄÁϵijýÆøÐÔÄܲâÊÔ£¬º½ÌìÆ÷ÈκÎÒ»´¦Î¢Ð¡µÄ·ÅÆøºÍÂ©Æø£¬¶¼»á²úÉúÒ»¸ö¸½¼ÓµÄ¼ÓËÙ¶È£¬¸Ä±äº½ÌìÆ÷µÄÔËÐйìµÀºÍ×Ë̬£¬Òò´Ë·ûºÏÃÀ±êASTM E595Äܹ»¼õÉÙ¶ÔÃô¸Ð»·¾³µÄÓ°ÏìÁ¦¡£ÄϾ©î£¶½¹«Ë¾ÒÑЭÖú¹úÄÚÆóҵ˳ÀûÉêÇëASTM E595ÈÈÕæ¿ÕÊÍÆø²âÊÔ¡£

Ëæ×ź½¿Õº½Ìì¼°5GÓ¦ÓõÄѸÃÍ·¢Õ¹£¬ÌØÊâµÄ¿Õ¼ä»·¾³¶Ôµç×ÓÔªÆ÷¼þµÄÊÍ·ÅÌØÐÔ£¨³öÆø£©Ò²Ìá³öÁËÌØ±ðÑϸñµÄÒªÇó¡£ÔÚ¿Õ¼äÕæ¿Õ»·¾³Ï£¬²ÄÁÏ·ÅÆøOutgassing test ºÍ½á¹¹·ÅÆøÊÇÒ»ÖÖ³£¼ûµÄÏÖÏó£¬Ëü¶Ôº½ÌìÆ÷ºÍ5G»úÕ¾µÄÕý³£Îȶ¨ÔËÐоßÓкܴóµÄÓ°Ïì¡£ÃÀ±êASTME595Êdz£ÓÃ·ÅÆø±ê×¼Ö®Ò»£¬ASTM E595±ê×¼ÒªÇó×ÜÖÊÁ¿¿÷Ëð£¨TML£©¡Ü1%ºÍ»Ó·¢ÎïÖÊÀäÄýÁ¿£¨CVCM£©¡Ü0.1%¡£


ASTM E595ÈÈÕæ¿ÕÊÍÆø²âÊÔ

ASTM E595 ÔÚÕæ¿Õ»·¾³ÖгýÆø×÷ÓÃÒýÆðµÄ×ÜÖÊÁ¿ËðʧºÍ»Ó·¢ÎïÖÊÀäÄýÁ¿µÄ²âÊÔ·½·¨
ASTM E595 Standard Test Method for Total Mass Loss and Collected Volatile Condensable Materials from Outgassing in a Vacuum Environment
 
ASTM E595ÈÈÕæ¿ÕÊÍÆø²âÊÔ-²âÊÔ·½·¨

ASTM E595³ýÆø²âÊÔ·½·¨°üº¬Ê¹ÓÃɸѡ¼¼ÊõÀ´È·¶¨µÄ²ÄÁÏÔÚÕæ¿Õ״̬ϵĻӷ¢ÐÔ¡£ÐèÒª²âÊÔÁ½¸ö²ÎÊý£º×ÜÖÊÁ¿¿÷Ëð£¨TML£©ºÍ»Ó·¢ÎïÖÊÀäÄýÁ¿£¨CVCM£©¡£ÁíÒ»¸ö²ÎÊýË®ÆûÁ¿(WVR), Ò²¿ÉÒÔÔÚÍê³É¶ÔTMLºÍCVCMµÄ²âÊÔºó»ñµÃ¡£
ASTM E595 outgassing test, This test method covers a screening technique to determine volatile content of materials when exposed to a vacuum environment. Two parameters are measured: total mass loss (TML) and collected volatile condensable materials (CVCM). An additional parameter, the amount of water vapor regained (WVR), can also be obtained after completion of exposures and measurements required for TML and CVCM
 
ASTM E595ÈÈÕæ¿ÕÊÍÆø²âÊÔ-²âÊÔ·¶Î§
¸÷ÖÖ¸÷ÑùµÄÓлú·Ö×Ó£¬¾ÛºÏÎïºÍÎÞ»ú²ÄÁ϶¼¿ÉÒÔ±»²âÊÔ¡£ÕâЩ²ÄÁϰüº¬£º¾ÛºÏ»ìºÏÎ·¢ÅݲÄÁÏ£¬µ¯ÐÔÌ壬±¡Ä¤£¬½º´ø£¬¾øÔµÌ壬ÊÕËõ¹Ü£¬½ºË®£¬Í¿ÁÏ£¬·ÄÖ¯ÃæÁÏ£¬ºÍÂÖ»¬ÓÍ£¬ÕâЩ²ÄÁÏ¿ÉÒÔÔÚԭʼ½ÓÊܵÄ״̬ϲâÊÔ£¬Ò²¿ÉÒÔͨ¹ý¶àÖÖ·½Ê½¹Ì»¯ºó²âÊÔ¡£
Many types of organic, polymeric, and inorganic materials can be tested by ASTM E595 outgassing test. These include polymer potting compounds,foams, elastomers, films, tapes, insulations, shrink  tubings, adhesives, coatings, fabrics, tie cords, and lubricants. The materials may be tested in the ¡°as-received¡± condition or prepared for test by various curing specifications.
 
ASTM E595ÈÈÕæ¿ÕÊÍÆø²âÊÔ-²âÊÔÏîÄ¿ºÍÒªÇó£º

TML £¨total mass loss£©×ÜÖÊÁ¿¿÷Ëð,ÒªÇó¡Ü1%
CVCM £¨collected volatile condensable materials£©»Ó·¢ÎïÖÊÀäÄýÁ¿, ÒªÇó¡Ü0.1%
WVR £¨the amount of water vapor regained£©Ë®ÆûÁ¿

ÄϾ©î£¶½¹«Ë¾Ãâ·Ñ×Éѯµç»°£º025-8658 3475  400-603-6575
꿅᣼
www.fire-test.com
ÓÊÏ[email protected]

¡­

 
ÄϾ©î£¶½¿Æ¼¼ÓÐÏÞ¹«Ë¾ °æÈ¨ËùÓÐ DIN5510 DIN5510-2
µØÖ·:Öйú½­ËÕÊ¡ÄϾ©Êн­¶«Öз118ºÅµÂÓ¯´óÏÃ16F  µç»°£º(+86) 025-8658 3475
´«Õ棺(+86) 025-8658 3457    ÓÊÏ[email protected] ËÕICP±¸12030029ºÅ-3 ËÕ¹«Íø°²±¸ 32010502010104ºÅ
ÄϾ©î£¶½¿Æ¼¼ÓÐÏÞ¹«Ë¾ÊÇÒ»¼Òרҵ´ÓÊÂDIN5510µÈ¸÷ÖÖ²»Í¬¹ú¼Ò±ê×¼»ú³µ²ÄÁÏ×èȼ¼°ÑÌÎí¶¾ÐԵIJâÊÔ¡¢×ÉѯµÄ»ú¹¹¡£