 Current Location£ºHome >> FAQ >> How long the BS6853 report valid time?

How long the BS6853 report valid time? How long the BS6853 certificate valid time?


The term of validity of BS6853 test report is prepared to do BS6853 testing many manufacturers and one of the more concern has been BS6853 testing and certification of the manufacturers. Nanjing Smart companies will provide detailed information about BS6853 for your.

BS6853:1999-Code of practice for fire precautions in the design and construction of passenger carrying trains.


BS6853 Standard mainly focuses on the following aspects:
BS476-6 test for fire propagation for products
BS476-7 determines the classification of the surface spread of flame of products.
BS4589-2 oxygen index test
BS4589-3 temperature rise index test
BS 6853 Annex B: smoke density test
BS 6853 Annex D: toxicity test
BS EN 4066/BS 4066-3: cable vertical flame combustion
BS EN 50266-2-4: cable multiple root bundle vertical flame combustion ( cable diameter¡Ý 12mm ), destroy the length of not more than 2.5m, through this test. The test mainly tests a plurality of bunched cables on the flame-retardant properties of size, testing the plurality of bunched cables vertical down position.
BS EN 50266-2-5: cable multiple root bundle vertical flame combustion ( cable diameter < 12mm ), destroy the length of not more than 2.5m, through this test. The test mainly tests a plurality of bunched cables on the flame-retardant properties of size, testing the plurality of bunched cables vertical down position.
DIN EN 50305 section 9.1.1: cable multiple root bundle vertical flame combustion ( 6mm < cable diameter < 12mm ) the need for the test cable and wire ( not including the data line ), the maximum failure length combustion test cable of not more than 2.5m.
DIN EN 50305 section 9.1.2: cable multiple root bundle vertical flame combustion ( cable diameter¡Ü 6mm requires the test cable and wire ( not including the data line ), the maximum failure length combustion test cable of not more than 2.5m.
DIN EN 50305 section 9.2: cable toxicity test of -CIT index of toxicity test
BS EN 60332-3-24/BS EN 60332-3-25: root bundle cable burning test